hw/arm/highbank: Default -drive to if=ide instead of if=scsi

These machines have no onboard SCSI HBA, and no way to plug one.
-drive if=scsi therefore cannot work.  They do have an onboard IDE
controller (sysbus-ahci), but fail to honor if=ide.

Change their default to if=ide, and add a TODO comment on what needs
to be done to actually honor -drive if=ide.

Cc: Rob Herring <robh@kernel.org>
Cc: Peter Maydell <peter.maydell@linaro.org>
Cc: qemu-arm@nongnu.org
Signed-off-by: Markus Armbruster <armbru@redhat.com>
Reviewed-by: Thomas Huth <thuth@redhat.com>
Message-Id: <1487153147-11530-6-git-send-email-armbru@redhat.com>
This commit is contained in:
Markus Armbruster 2017-02-15 11:05:44 +01:00
parent 7e465513c1
commit 2a7ae4ee50

View file

@ -363,6 +363,8 @@ static void calxeda_init(MachineState *machine, enum cxmachines machine_id)
sysbus_connect_irq(SYS_BUS_DEVICE(dev), 2, pic[82]);
}
/* TODO create and connect IDE devices for ide_drive_get() */
highbank_binfo.ram_size = ram_size;
highbank_binfo.kernel_filename = kernel_filename;
highbank_binfo.kernel_cmdline = kernel_cmdline;
@ -405,7 +407,8 @@ static void highbank_class_init(ObjectClass *oc, void *data)
mc->desc = "Calxeda Highbank (ECX-1000)";
mc->init = highbank_init;
mc->block_default_type = IF_SCSI;
mc->block_default_type = IF_IDE;
mc->units_per_default_bus = 1;
mc->max_cpus = 4;
}
@ -421,7 +424,8 @@ static void midway_class_init(ObjectClass *oc, void *data)
mc->desc = "Calxeda Midway (ECX-2000)";
mc->init = midway_init;
mc->block_default_type = IF_SCSI;
mc->block_default_type = IF_IDE;
mc->units_per_default_bus = 1;
mc->max_cpus = 4;
}